Vue de la page 41
4-4 Programmer’s Manual
BiDirRedundancy
Description
Enables Bi-Directional Redundancy, which specifies that good scans must
occur in both directions (forward and reverse) for the scan to be
complete.
Syntax
BiDirRedundancy
Parameters
BiDirRedundancy true Scans must occur in both directions
false Default
Return Values
None
Example
<SCRIPT src="./jsUltra.js"></SCRIPT>
<SCRIPT type="text/javascript">
GENERAL.BiDirRedundancy = false;
//Scans do not have to occur in both directions
SCANNER.CommitConfigChanges();
//Save Changes to the Scanner Configuration
</SCRIPT>
<OBJECT id=”GENERAL” style="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid:B1EED6A7-2259-442D-B273-71EBE93C8338>
</OBJECT> //Instantiate Class
<BODY>
<OBJECT id=”SCANNER” style="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid: AD3C761C-4BCC-403D-A68D-128ED702A417>
</OBJECT> //Instantiate Class
</BODY>